Back to top
Sidewall Type Fire Sprinkler
Sidewall Type Fire Sprinkler

Sidewall Type Fire Sprinkler

MOQ : 10 Pieces

Sidewall Type Fire Sprinkler Specification

  • Fire Extinguisher Type
  • Sprinkler (Sidewall Type)
  • Working Temperature
  • 57C, 68C, 79C, or as required
  • Shape
  • Rectangular Deflector Head
  • Operating Pressure
  • 0.35-1.2 MPa
  • Technology
  • Glass Bulb Activated Wet Sprinkler Technical
  • Mounting Type
  • Sidewall Horizontal (Wall Mounted)
  • Features
  • Quick Response, Corrosion Resistant, Uniform Spray Pattern
  • Control Type
  • Automatic
  • Installation Type
  • Wall-Mounted Horizontal Sidewall
  • Connectivity Type
  • Mechanical Connection (Threaded)
  • Coverage Area
  • Up to 21 square meters depending on installation
  • Fire Class
  • Class A & B
  • Coating Type
  • Chrome Plated / Brass Finish
  • Application
  • Fire Protection System for Building Interiors
  • Max Flow Rate
  • Varies as per Sprinkler Temperature Rating and Pressure
  • Diameter
  • 1/2 inch BSPT (15 mm)
  • Pressure
  • Up to 12 bar
  • Deflector Material
  • Brass
  • Maintenance
  • Low, Visual Inspection Recommended
  • Minimum Spacing
  • 1.8 m from adjacent sprinklers
  • Finish Options
  • Brass, Chrome, White Painted
  • Usage
  • Residential, Commercial, and Industrial Premises
  • Weight
  • Approximately 90-120 grams
  • Compliance Standard
  • UL Listed/FM Approved (Model dependent)
  • Orifice Size
  • 15 mm
  • K-Factor
  • 5.6 (80 Metric)
  • Response Type
  • Standard/Quick Response
  • Activation Element
  • Glass Bulb (Temperature-sensitive)
  • Spray Pattern
  • Half-circle (for wall installation)
  • Operating Medium
  • Water only
 

Sidewall Type Fire Sprinkler Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 500 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Sidewall Type Fire Sprinkler



Featured for both residential and commercial spaces, this brilliantly engineered Sidewall Type Fire Sprinkler is a must-have for modern fire safety. With a K-Factor of 5.6, it delivers terrific, uniform coverage up to 21 square meters, helping protect Class A & B fire zones. Decorated with a choice of chrome, brass, or white finishes, this sprinkler boasts a precision-built brass deflector, glass bulb activation, and durable, corrosion-resistant construction. Order today-its automatic operation, quick response, and low maintenance design ensure your interiors are guarded by reliable, UL/FM-compliant technology.

Versatile Protection for Modern Interiors

The Sidewall Type Fire Sprinkler operates with water, making it ideal for a variety of environments including residences, offices, factories, and shopping complexes. Its application covers fire protection systems across building interiors, offering primary competitive advantages such as rapid response, mechanical reliability, and corrosion-resistant performance. Suitable for Class A & B fires, it excels in projects demanding compliance, robust build, and efficient fire suppression methods, ensuring lasting security and peace of mind.


Sample Policy & Nationwide Supply Assurance

Samples are available at the lowest price for bulk orders, catering to quality-conscious clients. We supply and ship goods across the main domestic market in India, ensuring quick access from reliable manufacturers and suppliers. Our streamlined logistics guarantee delivery within a standard period, keeping project timelines intact. Whether for large commercial deployments or residential installations, our network ensures that every product reaches you promptly and efficiently.


FAQ's of Sidewall Type Fire Sprinkler:


Q: How does the Sidewall Type Fire Sprinkler activate during a fire emergency?

A: The sprinkler activates automatically when the temperature-sensitive glass bulb reaches a preset temperature (such as 57C, 68C, or 79C), causing it to burst and release water uniformly across the designated area.

Q: What are the key benefits of using this sidewall sprinkler for my building?

A: Key benefits include rapid fire response, easy wall-mounted installation, corrosion-resistant construction, UL/FM compliance, and coverage of up to 21 square meters, enhancing building safety and minimizing maintenance needs.

Q: Where should I install the Sidewall Type Fire Sprinkler for optimal coverage?

A: Install the sprinkler horizontally on the wall, maintaining a minimum spacing of 1.8 meters from adjacent units to ensure uniform spray pattern coverage as recommended by safety standards.

Q: What maintenance or inspection does this fire sprinkler require?

A: The unit requires only low maintenance-primarily periodic visual inspection to ensure unobstructed operation and that the activation glass bulb is intact and clean.

Q: Can this sprinkler system be used in industrial settings?

A: Yes, this Sidewall Type Fire Sprinkler is designed for use in residential, commercial, and industrial premises, making it highly adaptable for a range of fire protection applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Sprinklers Category

Concealed Type Fire Sprinkler

Concealed Type Fire Sprinkler

Minimum Order Quantity : 10 Pieces

Capacity : Flow/Discharge Based on Pressure and Time

Fire Extinguisher Type : Concealed Sprinkler

Working Temperature : 57C/68C (Standard)

Operating Pressure : 1.2 1.4 MPa

Max Flow Rate : 80110 L/min depending on pressure

Upright Type Fire Sprinkler

Upright Type Fire Sprinkler

Minimum Order Quantity : 10 Pieces

Capacity : For standard water supply

Fire Extinguisher Type : Sprinkler Head

Working Temperature : 68C (standard), Others available

Operating Pressure : Minimum 0.35 MPa

Max Flow Rate : 80115 L/min

Pendent Type Fire Sprinkler

Pendent Type Fire Sprinkler

Minimum Order Quantity : 10 Pieces

Capacity : Single Use per Activation

Fire Extinguisher Type : Sprinkler Head

Working Temperature : 57C to 68C (typical bulb rating)

Operating Pressure : 1.2 MPa Maximum

Max Flow Rate : 80100 L/min (varies by pressure)