Back to top
Concealed Type Fire Sprinkler
Concealed Type Fire Sprinkler

Concealed Type Fire Sprinkler

MOQ : 10 Pieces

Concealed Type Fire Sprinkler Specification

  • Operating Pressure
  • 1.2 - 1.4 MPa
  • Coverage Area
  • 12 to 16 square meters per sprinkler
  • Connectivity Type
  • Mechanical Connection (Piping)
  • Working Temperature
  • 57C/68C (Standard)
  • Features
  • Decorative Concealed Plate, Fast Response, Corrosion Resistant, Easy Installation, Low Profile Design
  • Fire Extinguisher Type
  • Concealed Sprinkler
  • Mounting Type
  • Flush Mount, Ceiling
  • Installation Type
  • Ceiling Mounted (Concealed)
  • Technology
  • Heat Sensitive Link with Concealed Cover Plate
  • Coating Type
  • Chrome Plated/White Painted (Concealed Plate)
  • Fire Class
  • Class A & B
  • Control Type
  • Automatic
  • Shape
  • Round Concealed Head
  • Application
  • Fire Safety, Ceiling Installation, Commercial and Residential Buildings
  • Max Flow Rate
  • 80-110 L/min depending on pressure
  • Diameter
  • 15 mm (1/2 Inch)
  • Capacity
  • Flow/Discharge Based on Pressure and Time
  • Pressure
  • 7-12 Bar
  • Material
  • Brass/Bronze Body with Stainless Steel Springs
  • Cover Plate Finishing
  • White or Custom Color Available
  • Bulb Size
  • 3 mm Standard Glass Bulb
  • Activation Temperature Ratings
  • 57C (135F), 68C (155F), Special orders available
  • Minimum Spacing
  • 2.4 meters from adjacent sprinkler
  • Thread Size
  • 1/2" BSPT/NPT
  • Maintenance
  • Minimal, Periodic Inspection Suggested
  • Discharge Coefficient (K-Factor)
  • K=5.6 (80) US (metric)
  • Response Time
  • Quick Response (Glass Bulb Thermal Element)
  • Spray Pattern
  • Pendent Downward Spray
  • Corrosion Resistance
  • High
 

Concealed Type Fire Sprinkler Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 500 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Concealed Type Fire Sprinkler



Upgrade your fire safety measures with our Scarce Concealed Type Fire Sprinkler, designed for both commercial and residential applications. Engineered with a classic brass/bronze body and stainless-steel springs, this top-tier sprinkler blends seamlessly into ceilings with its decorative, low-profile, and concealed cover plate. The premier quick-response glass bulb ensures fast activation, delivering reliability when it matters most. With a generous price cut, now is the ideal time to add to cart. Featuring high corrosion resistance, easy installation, and minimal maintenance, this is your trusted partner in fire protection.

Versatile Protection with Advanced Features

This Concealed Type Fire Sprinkler operates with a quick-response thermal glass bulb and a downward spray pattern, ensuring reliable fire suppression for Class A & B fires. Its high corrosion resistance and decorative custom-finish plate highlight its appeal for both commercial and residential spaces. Applications include shopping complexes, hotels, offices, residential towers, and other ceiling installations where discreet and premier protection is vital.


Order Completion and Export-Ready Packaging

Our sprinklers are packaged securely for domestic delivery and export markets, guaranteeing product integrity from dispatch to installation. With flexible payment terms and efficient order completion processes, you benefit from a seamless procurement experience. Shipping from leading FOB ports across India, we serve national and international markets, ensuring timely delivery and satisfaction for partners in the fire safety supply chain.


FAQ's of Concealed Type Fire Sprinkler:


Q: How does the Concealed Type Fire Sprinkler function in an emergency?

A: The sprinkler employs a heat-sensitive glass bulb that bursts at a specified temperature, releasing water in a downward spray to quickly suppress fires, offering rapid and effective class A & B fire response.

Q: What makes this sprinkler system suitable for both residential and commercial applications?

A: Its low-profile concealed design, high corrosion resistance, and quick response time make it ideal for offices, hotels, shopping centers, and residential buildings alike, blending safety with aesthetics.

Q: When should the Concealed Fire Sprinkler be inspected or maintained?

A: Periodic inspection is suggested for optimal performance, but maintenance requirements are minimal due to durable materials and robust construction.

Q: Where can custom color finishes for the cover plate be applied?

A: Custom color cover plates are available upon special order, enabling seamless visual integration into any ceiling decor-be it corporate, commercial, or residential environments.

Q: What are the installation requirements for maximum efficiency?

A: Mount each sprinkler in the ceiling with a minimum spacing of 2.4 meters from adjacent units, ensuring a coverage area of 12-16 square meters per sprinkler and effective fire suppression as per guidelines.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Sprinklers Category

Upright Type Fire Sprinkler

Upright Type Fire Sprinkler

Minimum Order Quantity : 10 Pieces

Operating Pressure : Minimum 0.35 MPa

Coverage Area : 1221 m2

Features : Corrosion Resistant, Quick Response

Working Temperature : 68C (standard), Others available

Diameter : 15 mm (1/2 inch)

Pendent Type Fire Sprinkler

Pendent Type Fire Sprinkler

Minimum Order Quantity : 10 Pieces

Operating Pressure : 1.2 MPa Maximum

Coverage Area : 912 sqm per sprinkler

Features : Corrosion Resistant, Fast Response

Working Temperature : 57C to 68C (typical bulb rating)

Diameter : 15 mm (1/2 inch)

Sidewall Type Fire Sprinkler

Sidewall Type Fire Sprinkler

Minimum Order Quantity : 10 Pieces

Operating Pressure : 0.351.2 MPa

Coverage Area : Up to 21 square meters depending on installation

Features : Quick Response, Corrosion Resistant, Uniform Spray Pattern

Working Temperature : 57C, 68C, 79C, or as required

Diameter : 1/2 inch BSPT (15 mm)